Allure of the Seas

Royal Caribbean International · CDC Vessel Sanitation Program record

Satisfactory: score 98 out of 100

Latest inspection April 29, 2026 · CDC inspection report

CDC’s passing mark is 86 out of 100.

Cruise line
Royal Caribbean International
Inspections in this snapshot
23
Currently on the Green Sheet
Yes

Score history

Dates and scores are as CDC's inspection search returned them. Failing scores are shaded. Each report link goes to the official CDC page.

Score history for Allure of the Seas

Inspection dateScore and official resultCDC report
April 29, 202698 SatisfactoryOfficial report
November 8, 202597 SatisfactoryOfficial report
December 16, 202497 SatisfactoryOfficial report
January 26, 202499 SatisfactoryOfficial report
February 12, 2023100 SatisfactoryOfficial report
December 1, 201999 SatisfactoryOfficial report
May 12, 201999 SatisfactoryOfficial report
July 8, 201897 SatisfactoryOfficial report
December 31, 201786 SatisfactoryOfficial report
March 19, 201797 SatisfactoryOfficial report
January 15, 201788 SatisfactoryOfficial report
June 5, 2016100 SatisfactoryOfficial report
February 14, 201697 SatisfactoryOfficial report
March 18, 201592 SatisfactoryOfficial report
November 9, 2014100 SatisfactoryOfficial report
August 31, 201497 SatisfactoryOfficial report
May 18, 201498 SatisfactoryOfficial report
July 28, 201399 SatisfactoryOfficial report
December 12, 201298 SatisfactoryOfficial report
August 5, 201297 SatisfactoryOfficial report
February 5, 201295 SatisfactoryOfficial report
July 24, 2011100 SatisfactoryOfficial report
December 29, 201099 SatisfactoryOfficial report

Latest official findings

The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.

Drinking water (5 findings)

Item 08

Where it was found: Potable Water-Pipe Disinfection Log

Official finding: On 25 April 2026, during a pipe disinfection process, the specific free chlorine residual value was not listed in the log after flushing as per the VSP 2025 Environmental Public Health Standards.

Official recommendation

Flush the disinfected parts of the potable water system with potable water or otherwise dechlorinate until the free halogen residual is less than or equal to 5.0 mg/L (ppm). Document the free halogen test result with a specific value measured.

Item 06

Where it was found: Potable Water-Legionella Potable Water Sampling Plan

Official finding: A Legionella sample from neither of the two potable water heaters was included in the previous six-month sampling plan as per the VSP 2025 Environmental Public Health Standards.

Official recommendation

Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel. Take follow-up actions when Legionella is detected based on the type of Legionella found, the concentration (for example in CFU/ml), and the extent of colonization. Actions can include (1) Review of the water management program; (2) Root cause analysis to understand possible reasons for Legionella growth; (3) Updates to the water management program if needed. Consider retesting fixtures or devices where Legionella was detected to confirm the effectiveness of the response and to determine if remediation is needed. For additional guidance, see ASHRAE Guideline 12, Appendix C5. The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing.

Item 08

Where it was found: Potable Water-Reverse Osmosis Units #3 and #4

Official finding: The permeate water lines directed to the potable water system were not striped blue/gray/blue as they exited the reverse osmosis units.

Official recommendation

Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines, including potable water supply lines in technical lockers, at 5 meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.

Item 08

Where it was found: Potable Water-Bunker Line Dosing Station

Official finding: The backflow prevention devices for the eye wash sink, and the deck cleaning hose were in disrepair with blocked atmospheric vents.

Official recommendation

Maintain backflow prevention devices in good repair.

Item 05

Where it was found: Potable Water-Deck 14 - Distant Point

Official finding: The manually measured free chlorine residual level was greater than 0.2 mg/L (ppm) from the halogen analyzer’s measurement. Calibration was conducted immediately.

Official recommendation

Ensure the free halogen residual measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free halogen residual measured by the manual test.

Galleys and dining rooms (38 findings)

Item 27

Where it was found: Galley-Deck 5 - Forward Entrance

Official finding: The edges of three mobile, stainless-steel trolleys were dented and damaged, creating sharp difficult-to-clean surfaces. Brown and silver residue flaked from the damaged surfaces.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 21

Where it was found: Buffet-Deck 17 - Suite Lounge

Official finding: Several cords from the counter-mounted coffee machine were resting on the countertop. Additionally, the countertop surface around the cords was soiled with an accumulation of debris greater than a day's worth. The venue was not in operation at the time of inspection. This was corrected immediately.

Official recommendation

Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 27

Where it was found: Buffet-Deck 17 - Suite Lounge

Official finding: The countertop surface around the counter-mounted coffee machine cords was soiled with an accumulation of debris greater than a day's worth. The venue was not in operation at the time of inspection. This was corrected immediately.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 27

Where it was found: Galley-Deck 17 - Coastal Kitchen - Side Station

Official finding: A clean storage rack with previously cleaned and sanitized utensils was soiled with a strand of human hair. The venue was not in operation at the time of the inspection. This was corrected immediately.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 28

Where it was found: Galley-Deck 17 - Coastal Kitchen - Side Station

Official finding: Previously cleaned and sanitized utensils were stored on a clean storage rack soiled with a strand of human hair. The venue was not in operation at the time of the inspection. This was corrected immediately.

Official recommendation

Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination.

Item 36

Where it was found: Galley-Deck 17 - Coastal Kitchen

Official finding: The light intensity along the external side of the reach-in refrigerators measured less than 220 lux. This was corrected prior to the end of the inspection.

Official recommendation

Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces. Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.

Item 21

Where it was found: Buffet-Deck 15 - Crown Lounge

Official finding: The counter mounted coffee machine’s front left leg mount was not adequately sealed to the countertop exposing an open seam.

Official recommendation

Install table-mounted equipment that is not easily movable to allow cleaning of the equipment and areas underneath and around the equipment in one of the following ways: (1) Sealed to the table. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 20

Where it was found: Galley-Deck 15 - Mason Jar

Official finding: The walk-in refrigerator did not have an internal temperature measuring device inside of the unit. This was corrected immediately.

Official recommendation

Ensure food temperature-measuring devices are provided and available for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.

Item 21

Where it was found: Buffet-Deck 15 - Solarium Bistro - Gluten Free Station

Official finding: The countertop had an open seam on the right corner underneath the sneeze guard. This was corrected immediately.

Official recommendation

Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 22

Where it was found: Galley-Deck 16 - Windjammer

Official finding: The wash compartment of the flight-type warewashing machine was spraying into the final sanitizing rinse compartment as plates were being sanitized. This was corrected immediately.

Official recommendation

Ensure the warewashing machine wash and rinse tanks are equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.

Item 22

Where it was found: Galley-Deck 16 - Windjammer

Official finding: Two final sanitizing rinse nozzles to the glasswash rack type machine did not have a fan like spray pattern.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.

Item 33

Where it was found: Galley-Deck 8 - 115 Central Park

Official finding: The deckhead light fixture above the preparation station had an accumulation of water. This was corrected immediately.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 36

Where it was found: Buffet-Deck 16 - Windjammer - Pastry Station

Official finding: The light bulb shield around the hanging deckhead light fixture over the serving line was shattered. This venue was in operation at the time of the inspection. No food was impacted.

Official recommendation

Ensure light bulbs are shielded, coated, or otherwise shatter resistant in areas with exposed food; clean equipment, utensils, and linens; or unwrapped single-service articles and single-use articles.

Item 21

Where it was found: Galley-Deck 5 - Forward Entrance

Official finding: The edges of three mobile, stainless-steel trolleys were dented and damaged, creating sharp difficult-to-clean surfaces. Brown and silver residue flaked from the damaged surfaces.

Official recommendation

Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 22

Where it was found: Galley-Deck 5 - Portside Warewashing Area

Official finding: Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.

Item 33

Where it was found: Galley-Deck 5 - Portside Warewashing Area

Official finding: Steam from the conveyor-type warewashing machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 37

Where it was found: Galley-Deck 5 - Portside Warewashing Area

Official finding: Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam.

Official recommendation

Ensure all food preparation, warewashing areas, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them.

Item 22

Where it was found: Galley-Deck 5 - Portside Warewashing Area

Official finding: One plastic container with 25 soiled glasses was stored directly on the deck underneath the wash compartment of conveyor-type warewashing machine. Crew were actively conducting warewashing operations. Crew initiated corrective action.

Official recommendation

Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for utensil holding before cleaning and after sanitizing.

Item 33

Where it was found: Galley-Deck 5 - Portside Warewashing Area

Official finding: One plastic container with 25 soiled glasses was stored directly on the deck underneath the wash compartment of conveyor-type warewashing machine. Crew were actively conducting warewashing operations. Crew initiated corrective action.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 19

Where it was found: Galley-Deck 5 - Walk-In Freezer Unit # 5411

Official finding: A layer of ice accumulated directly on corn stored inside a plastic container on the top shelf of the unit. The plastic lid was ajar, causing cold air to freeze directly on the corn. Crew initiated corrective action.

Official recommendation

Protect food from contamination that may result from a physical, chemical, biological origin. Protect food from contamination by storing the food: (1) Covered or otherwise protected.

Item 17

Where it was found: Galley-Deck 5 - Pantry

Official finding: No time control plan was physically posted inside the pantry area located off of the main galley. The nearest posted plan that included the set up and discard times for the pantry's rolling fridge #339, which was physically identified as a time control, was in the main preparation area on the opposite side of the galley. Crew initiated corrective action.

Official recommendation

Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.

Item 16

Where it was found: Galley-Deck 5 - Walk-In Refrigeration Unit # 5411

Official finding: One, open cardboard container of soy milk was not labeled with a 7-day discard label. Crew could not identify when the container of milk was opened. Crew initiated corrective action.

Official recommendation

Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.

Item 22

Where it was found: Galley-Deck 5 - Potwashing Area

Official finding: Water spewed from the bottom right side of the front door for the potwashing machine and pooled on the deck below.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.

Item 35

Where it was found: Galley-Deck 5 - Potwashing Area

Official finding: Water spewed from the bottom right side of the front door for the potwashing machine and pooled on the deck below.

Official recommendation

Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.

Item 20

Where it was found: Galley-Deck 4 - Bakery

Official finding: The left and right edges of the in-use dough sheeter belt were frayed, with numerous difficult-to-clean stringy edges.

Official recommendation

Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices. Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.

Item 19

Where it was found: Galley-Deck 4 - Bakery

Official finding: A plastic rolling container of pumpernickel bread crumbs, removed from its original container, was not identified with the common name of the item. Crew initiated corrective action.

Official recommendation

Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.

Item 22

Where it was found: Galley-Deck 4 - Warewashing Area

Official finding: Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the portside conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.

Item 33

Where it was found: Galley-Deck 4 - Warewashing Area

Official finding: Steam from the conveyor-type warewashing machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 37

Where it was found: Galley-Deck 4 - Warewashing Area

Official finding: Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the portside conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.

Official recommendation

Ensure all food preparation, warewashing areas, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them.

Item 20

Where it was found: Galley-Deck 3 - Forward Beverage Station

Official finding: There were two tears in the food splash surface of the front panel for the deck mounted ice machine, creating two difficult to clean, rough surfaces. Brown and orange residue accumulated around these two difficult to clean surfaces.

Official recommendation

Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints. Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.

Item 26

Where it was found: Galley-Deck 3 - Forward Beverage Station

Official finding: There were two tears in the food splash surface of the front panel for the deck mounted ice machine, creating two difficult to clean, rough surfaces. Brown and orange residue accumulated around these two difficult to clean surfaces.

Official recommendation

Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Item 33

Where it was found: Dining Room-Deck 4 - Izumi Teppanyaki

Official finding: The edges of the swinging doors to the crew area of the two teppanyaki grills were in disrepair, with rough surfaces exposing the difficult-to-clean wood underneath.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.

Item 34

Where it was found: Galley-Deck 2 - Hot Preparation Area

Official finding: Water steadily leaked from the cold-water supply pipe for the utility sink located next to the preparation counter and pooled on the deck underneath.

Official recommendation

Ensure the plumbing system in food areas is in good repair.

Item 33

Where it was found: Galley-Deck 2 - Hot Preparation Area

Official finding: Water pooled on the deck underneath the utility sink’s cold-water supply pipe that was in disrepair.

Official recommendation

Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Item 19

Where it was found: Galley-Deck 2 - Dry Storage Area

Official finding: Three plastic rolling containers of flour, removed from their original containers, were not identified with the common name of the item. Crew initiated corrective action.

Official recommendation

Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.

Item 22

Where it was found: Galley-Deck 2 - Scullery

Official finding: Water steadily spewed from the soiled end of the conveyor type warewashing machine and dripped from the soiled landing onto the deck below. The first set of spray arms was misaligned, causing water to spray towards the entrance of the machine.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.

Item 35

Where it was found: Galley-Deck 2 - Scullery

Official finding: Water pooled on the deck below the soiled end of the conveyor type warewashing machine. The first set of spray arms was misaligned, causing water to spray towards entrance of the machine.

Official recommendation

Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.

Item 33

Where it was found: Galley-Deck 16 - Windjammer

Official finding: A removable rug at the starboard side entrance of the galley had an accumulation of water. Additionally, the deck underneath the rug was unfinished.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.

Medical center (2 findings)

Item 11

Where it was found: Medical-Acute Gastroenteritis (AGE) Log

Official finding: A food employee had symptom onset at 0800 on 16 February 2026 and did not report to medical until 17 February 2026 at 0058. The food employee went to work and to the crew mess after their symptom onset and before they reported to medical. A food risk assessment was completed. Corrective actions were taken.

Official recommendation

When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document date and time of last symptom and clearance to return to work; (4) Review [when possible] any reportable AGE cases among passengers or crew reported after the food employee's illness onset for epidemiologic link/connection. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.

Item 11

Where it was found: Medical-Acute Gastroenteritis (AGE) Log

Official finding: A food employee had symptom onset at 2300 on 16 February 2026 and did not report to medical until 17 February 2026 at 0724. The food employee went to work before reporting to medical. A food risk assessment was completed. Corrective actions were taken.

Official recommendation

When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document date and time of last symptom and clearance to return to work; (4) Review [when possible] any reportable AGE cases among passengers or crew reported after the food employee's illness onset for epidemiologic link/connection. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.

Other inspection items (2 findings)

Item 24

Where it was found: Bar-Deck 15 - Lime and Coconut Bar - Starboard Side

Official finding: The chlorine solution in the sanitizing bucket measured 25 ppm. This was corrected immediately.

Official recommendation

Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).

Item 22

Where it was found: Bar-Deck 15 - Lime and Coconut Bar - Port Side

Official finding: The hood-type warewashing machine had been out of order as of 28 April 2026.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction.

Pest and insect management (1 finding)

Item 39

Where it was found: Food Service General-Integrated Pest Management

Official finding: Flies were in the following food areas:

  • Deck 17
  • Suite Lounge
  • One fly was over the handwashing station.
  • Deck 2
  • Crew Mess
  • Two flies were around the buffet beverage station.
Official recommendation

Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.

Swimming pools and whirlpools (1 finding)

Item 10

Where it was found: Recreational Water Facilities-All Pools

Official finding: The safety lines on the flotation devices were not easily accessible, preventing the devices from being used as designed.

Official recommendation

Provide a rescue or shepherd’s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3.3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency.

Gastrointestinal outbreak notices

These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.

Official outbreak notices collected for this ship

Sailing datesCausative agentCase countsSource
5/20-5/24, 2024UnknownPassengers: 121 of 6,364 (1.9%). Crew: 3 of 2,143 (0.14%).CDC notice

Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.