The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.
Drinking water (9 findings)
Item 08
Where it was found: Potable Water-Bunkering Records
Official finding: No shoreside pH pretest result was documented on the 24 November 2025 potable water bunkering record. The record field was left blank.
Official recommendation
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
Item 06
Where it was found: Potable Water-Far Point Chart-Analyzer Records
Official finding: The far point analyzer-chart recorder charts had a gap in recording without notation explaining the event on the following dates and times:
21 November from 0945 until 1100
13 November from 0930 until 1115
Official recommendation
Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system. If electronic data loggers are used instead of chart recorders, record notations of any unusual events in the potable water system log.
Item 06
Where it was found: Potable Water-Production Records
Official finding: No documentation of halogen and pH analyzer-chart recorder calibration was provided on the potable water production records for December 2, 3, and 4. These fields were left blank and no notations were recorded on the charts.
Official recommendation
Calibrate halogen and pH analyzer-chart recorders or data loggers used in lieu of manual tests and logs, at the beginning of bunkering or production and each time bunkering or production is restarted. Ensure the calibration is recorded on the chart or logbook (e.g. calibration done, checked, verified, or similar language).
Ensure the free halogen residual and pH measured by the halogen/pH analyzer are accurate to within 0.2 mg/L (ppm) of the free halogen residual and 0.2 of the pH as measured by the manual test.
Item 08
Where it was found: Potable Water-System Disinfection Records
Official finding: Crew could not provide disinfection records for the following routine repairs and stated they used the emergency disinfection procedure.
Maintain documentation of all potable water system inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and the measured free halogen residual after flushing. Flush the disinfected parts of the potabale water system with potable water or otherwise dechlorinate until the free halogen residual is less than or equal to 5.0 mg/L (ppm). Document the free halogen test result with a specific value measured.
Item 07
Where it was found: Potable Water-System Disinfection Records
Official finding: Crew stated they used the emergency disinfection procedure (200 ppm for 1 hour) for the following routine repairs:
Disinfect the potable water system after potential contamination by increasing the free halogen residual to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
Item 06
Where it was found: Potable Water-Legionella Sampling
Official finding: Salon & pedicure devices and the hot water return lines were not included in the Legionella sampling records for the previous six months. (2025 VSP Environmental Public Health Standard)
Official recommendation
Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel.
Take follow-up actions when Legionella is detected based on the type of Legionella found, the concentration (for example in CFU/ml), and the extent of colonization. Actions can include (1) Review of the water management program; (2) Root cause analysis to understand possible reasons for Legionella growth; (3) Updates to the water management program if needed. Consider retesting fixtures or devices where Legionella was detected to confirm the effectiveness of the response and to determine if remediation is needed. For additional guidance, see ASHRAE Guideline 12, Appendix C5.
The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°–113°F, 25°–45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing.
Item 08
Where it was found: Potable Water-Deck 1 - Engine Room Technical Water Striping
Official finding: The technical water faucet outside of reverse osmosis unit # 1 was striped blue/gray/blue; this fixture was not directed towards the potable water system. Additionally, the piping surrounding the dedicated technical water evaporator was striped blue/gray/blue. This evaporator was not directed towards the potable water system. Crew initiated corrective action.
Official recommendation
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
Item 08
Where it was found: Potable Water-Deck 3 - Portside Bunkering Station
Official finding: The portside bunker filling line did not have a screw cap with a noncorroding chain. Crew stated this component was awaiting delivery to the ship and wrapped the filling line in cellophane to protect it.
Official recommendation
Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
Item 08
Where it was found: Potable Water-Deck 7 - HVAC Room # 7123D
Official finding: The potable water supply lines for the handwashing sink inside the HVAC room were not striped blue/green/blue. Crew initiated corrective action.
Official recommendation
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
Galleys and dining rooms (8 findings)
Item 27
Where it was found: Provisions-Deck 3 - Pastry Freezer
Official finding: An excessive amount of ice and frost accumulated on the shelves nearest the freezer door.
Official recommendation
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item 30
Where it was found: Dining Room-Deck 6 - Talaat Nam Sushi Bar
Official finding: The crew handwash sink did not have soap or a waste receptacle.
Official recommendation
Ensure a handwashing station includes a sink, soap dispenser, single-use towel dispenser, and waste receptacle.
Item 21
Where it was found: Dining Room-Deck 6 - Talaat Nam Sushi Bar
Official finding: The printer power cable lay directly on the preparation counter, making cleaning difficult.
Official recommendation
Ensure equipment that is fixed because it is not easily movable is installed in one of the following ways: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment. Elevate cords above the counter.
Item 16
Where it was found: Galley-Deck 4 - Evrima Hot Galley
Official finding: One raw chicken breast stored in the refrigerator under the grill measured 43°F by the inspector and 42°F by the chef. The chicken was discarded.
Official recommendation
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, or 5°C (41°F) or less.
Item 20
Where it was found: Preparation Room-Deck 3 - Butcher
Official finding: One undercounter refrigerator had been out of service since the previous night.
Official recommendation
Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item 38
Where it was found: Preparation Room-Deck 3 - Butcher
Official finding: An unused meat band saw was stored in this area; crew stated they requested removal, and that it is unused because it breaks easily and the design is less safe to use.
Official recommendation
Ensure only articles necessary for the operation of food service areas are stored in food preparation, food storage, and warewashing areas.
Item 33
Where it was found: Provisions-Deck 3 - Meat Freezer
Official finding: Liquid from an unknown source dripped from two different bulkhead locations and accumulated on the deck as piles of ice.
Official recommendation
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item 19
Where it was found: Provisions-Deck 3 - Pastry Freezer
Official finding: An excessive amount of ice and frost accumulated on packaged breads and pastries on the shelf nearest the freezer door.
Official recommendation
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; (6) At least 150 millimeters (6 inches) above the deck on shelving units.
Medical center (2 findings)
Item 02
Where it was found: Medical-Reportable Acute Gastroenteritis (AGE) Log
Official finding: The downloadable AGE surveillance log did not contain a field for 'Comments/Notes.' (2025 VSP Environmental Public Health Standards)
Official recommendation
Ensure the AGE surveillance log includes a Comments/Notes column as specified in the AGE template located at https://www.cdc.gov/vessel-sanitation/php/communications-resources/index.html.
Item 11
Where it was found: Medical-Late Reporting Food Employee
Official finding: A food employee with acute gastroenteritis (AGE) symptom onset at 1630 on 27 November 2025 did not report to the medical center until 1825, after attending a team meeting with other food employees. Medical crew conducted follow-up consultations with all in attendance at the meeting. The crew member received disciplinary action.
Official recommendation
When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document date and time of last symptom and clearance to return to work; (4) Review [when possible] any reportable AGE cases among passengers or crew reported after the food employee's illness onset for epidemiologic link/connection.
Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.
When nonfood employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document the date and time of last symptom and clearance to return to work.
Other inspection items (3 findings)
Item 21
Where it was found: Bar-Deck 6 - The Bar
Official finding: Condensate accumulated around the undercounter freezer's seal and door, due to the gasket being in disrepair. Temperatures inside the freezer were not impacted.
Official recommendation
Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact and tight and adjusted in accordance with manufacturer's specifications.
Item 21
Where it was found: Bar-Deck 4 - Living Room Bar
Official finding: An excessive amount of corrosion and rust debris accumulated in the corner undercounter technical compartment.
Official recommendation
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item 28
Where it was found: Pantry-Deck 4 - Living Room Bar
Official finding: Previously cleaned and sanitized metal tea kettle warming covers were double stacked, which did not allow them to air dry properly. Condensate accumulated on the non-food contact surfaces of the covers.
Official recommendation
Store clean equipment and utensils: (1) In a self-draining position that allows air drying; (2) Covered or inverted.
Pest and insect management (1 finding)
Item 39
Where it was found: Bar-Integrated Pest Management
Official finding: Flies were seen in the following food areas:
Deck 4
Living Room Bar: Three fruit flies around the bar.
Deck 4
Wine Bolt: One fruit fly near the wine counter.
Official recommendation
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Swimming pools and whirlpools (2 findings)
Item 22
Where it was found: Galley-Deck 5 - Pool House
Official finding: The hood-type dishwash machine was out of service since the previous evening. Crew transported dishes to a different deck.
Official recommendation
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item 16
Where it was found: Galley-Deck 5 - Pool House
Official finding: One tray of raw ground beef patties was inside a time control trolley without a time control sticker. The other tray of potentially hazardous food in the trolley did have the correct sticker. The Pool House is in operation for more than 4 hours.
Official recommendation
If time without temperature control is used as the public health control with a maximum of 4 hours, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control; (a) Food may have an initial temperature of 21°C (70°F) or less before placement on time control if it is a ready-to-eat fruit or vegetable that becomes a TCS/PHF after cutting OR it is a ready-to-eat hermetically sealed food that becomes a TCS/PHF after opening AND (i) The food temperature does not exceed 21°C (70°F) within 4 hours from the time it became a TCS/PHF; (ii) The food is marked or otherwise identified to indicate 4 hours past the time it became a TCS/PHF (regardless of whether the time between service setup and closing exceeds 4 hours). (2) Is not to be placed on temperature control again; (3) Is marked or otherwise identified to indicate the time 4 hours past the time when the food is removed from temperature control if the time between service setup and closing is greater than 4 hours; (a) If time control unit meant to be cold holding or hot holding is not operational or used as intended, the unit is considered a counter, and the food stored within it must be labeled with its 4-hour discard time; (b) Containers of TCS/PHF under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours. (4) Is discarded within 4 hours of placement on time control.
Gastrointestinal outbreak notices
No official CDC outbreak notice in the listings we collected is clearly matched to this ship. That is not a guarantee that no illness occurred; it only means none of the posted notices we have were matched here. See the outbreak list.
Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.