Radiance of the Seas

Royal Caribbean International · CDC Vessel Sanitation Program record

Satisfactory: score 97 out of 100

Latest inspection March 23, 2026 · CDC inspection report

CDC’s passing mark is 86 out of 100.

Cruise line
Royal Caribbean International
Inspections in this snapshot
42
Currently on the Green Sheet
Yes

Score history

Dates and scores are as CDC's inspection search returned them. Failing scores are shaded. Each report link goes to the official CDC page.

Score history for Radiance of the Seas

Inspection dateScore and official resultCDC report
March 23, 202697 SatisfactoryOfficial report
November 14, 202595 SatisfactoryOfficial report
July 13, 202599 SatisfactoryOfficial report
March 15, 202595 SatisfactoryOfficial report
July 21, 2024100 SatisfactoryOfficial report
March 28, 202498 SatisfactoryOfficial report
June 18, 202398 SatisfactoryOfficial report
August 4, 201995 SatisfactoryOfficial report
June 24, 201898 SatisfactoryOfficial report
August 6, 2017100 SatisfactoryOfficial report
May 5, 2017100 SatisfactoryOfficial report
May 25, 2016100 SatisfactoryOfficial report
August 16, 201599 SatisfactoryOfficial report
June 7, 2015100 SatisfactoryOfficial report
August 20, 201499 SatisfactoryOfficial report
April 26, 201489 SatisfactoryOfficial report
September 11, 201395 SatisfactoryOfficial report
May 10, 201397 SatisfactoryOfficial report
August 26, 201299 SatisfactoryOfficial report
April 21, 201298 SatisfactoryOfficial report
August 23, 201196 SatisfactoryOfficial report
April 16, 201198 SatisfactoryOfficial report
June 13, 2010100 SatisfactoryOfficial report
December 21, 200999 SatisfactoryOfficial report
May 19, 200999 SatisfactoryOfficial report
November 9, 200897 SatisfactoryOfficial report
April 20, 200894 SatisfactoryOfficial report
October 21, 200795 SatisfactoryOfficial report
April 14, 200796 SatisfactoryOfficial report
November 11, 200696 SatisfactoryOfficial report
June 6, 200695 SatisfactoryOfficial report
October 15, 200594 SatisfactoryOfficial report
May 19, 200595 SatisfactoryOfficial report
January 19, 200599 SatisfactoryOfficial report
July 12, 200497 SatisfactoryOfficial report
December 9, 200396 SatisfactoryOfficial report
June 23, 200399 SatisfactoryOfficial report
December 22, 200293 SatisfactoryOfficial report
July 11, 200295 SatisfactoryOfficial report
February 17, 200299 SatisfactoryOfficial report
September 21, 200195 SatisfactoryOfficial report
April 30, 200190 SatisfactoryOfficial report

Latest official findings

The official report lists the following findings. The wording is quoted from CDC, grouped by the area of the ship so it is easier to read. We do not change the inspector's wording.

Drinking water (4 findings)

Item 06

Where it was found: Potable Water-Bunkering Analyzer-Chart Recorder

Official finding: The analyzer-chart recorder was not maintained in proper calibration during the 23 March 2026 bunkering of potable water. The analyzer-chart recorder measured a chlorine residual of 2.80 mg/L (PPM), while manual tests conducted by crew and the inspector measured residuals of 2.46 and 2.36 mg/L (PPM). Additional manual tests measured chlorine residual of 2.42 and 2.60 mg/L (PPM), while the analyzer-chart recorded displayed a residual of 2.22 mg/L (PPM). Crew initiated corrective action.

Official recommendation

Ensure the free halogen residual and pH measured by the halogen/pH analyzer are accurate to within 0.2 mg/L (ppm) of the free halogen residual and 0.2 of the pH as measured by the manual test.

Item 08

Where it was found: Potable Water-Evaporator Room

Official finding: The backwash discharge line from the mineralizer to the gray water tank was striped blue/gray/blue. Crew initiated corrective action.

Official recommendation

Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.

Item 06

Where it was found: Potable Water-Bunkering Records

Official finding: The 16 March 2026 potable water bunkering record identified potable water bunkering stopped at 1117 due to low water levels and resumed at 1137 without documentation that the analyzer-chart recorder was calibrated prior to restarting.

Official recommendation

Calibrate halogen and pH analyzer-chart recorders or data loggers used in lieu of manual tests and logs, at the beginning of bunkering or production and each time bunkering or production is restarted. Ensure the calibration is recorded on the chart or logbook (e.g. calibration done, checked, verified, or similar language).

Item 06

Where it was found: Potable Water-Legionella Sampling Records

Official finding: The ship's Legionella sampling records did not include testing conducted at hot water heaters. (New VSP 2025 Environmental Public Health Standard)

Official recommendation

Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel. The Legionella sampling plan must include a selection of the following locations: (2) Water heaters and hot water storage.

Galleys and dining rooms (18 findings)

Item 16

Where it was found: Galley-Deck 11 - Windjammer Preparation Area

Official finding: The internal temperatures of ten bags of shredded cheese stored inside walk-in refrigerator A-11731 ranged from 42°F to 47°F when measured using a calibrated thermometer. The bags were stacked on top of each other inside an upright food transportation trolley with the door closed, restricting airflow for proper cold holding. Crew initiated corrective action.

Official recommendation

Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.

Item 36

Where it was found: Buffet-Deck 11 - Windjammer Starboard Beverage Station

Official finding: The light intensity measured less than 220 lux at the juice dispensing area.

Official recommendation

Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces. Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.

Item 08

Where it was found: Buffet-Deck 11 - Windjammer - Beverage Station - Portside

Official finding: The backflow prevention device on the potable water line for the counter-mounted coffee machine was in disrepair with the atmospheric vents blocked.

Official recommendation

Maintain backflow prevention devices in good repair.

Item 27

Where it was found: Buffet-Deck 11 - Windjammer Portside Beverage Station

Official finding: Water pooled in the bottom of the undercounter technical compartment near the compressor.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 34

Where it was found: Buffet-Deck 11 - Windjammer Portside Beverage Station

Official finding: The undercounter compressor drain tube was not directed towards the deck drain, causing excess water to pool in the bottom of the technical compartment.

Official recommendation

Ensure the plumbing system in food areas is in good repair.

Item 20

Where it was found: Buffet-Deck 11 - Windjammer Portside Buffet Station

Official finding: Slotted fasteners were installed in the food-splash zones of two counter-mounted heating lamps. Crew initiated corrective action.

Official recommendation

Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices. Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.

Item 36

Where it was found: Buffet-Deck 11 - Windjammer - Center Island

Official finding: The shatter-resistant coating on two portable heating lamp bulbs at the meat carving station was peeling. Crew initiated corrective action.

Official recommendation

Ensure light bulbs are shielded, coated, or otherwise shatter resistant in areas with exposed food; clean equipment, utensils, and linens; or unwrapped single-service articles and single-use articles. Protect an infrared or other heat lamp against breakage by a shield surrounding and extending beyond the bulb so only the face of the bulb is exposed.

Item 26

Where it was found: Galley-Deck 11 - Windjammer Izumi Preparation Area

Official finding: One previously cleaned and sanitized cutting board was stored on a clean storage rack with food staining on the food-contact surfaces. Crew initiated corrective action.

Official recommendation

Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.

Item 21

Where it was found: Galley-Deck 11 - Windjammer Hot Preparation Line

Official finding: The door hinges on the hot line undercounter refrigerator were in disrepair, preventing the door from forming a tight seal when closed.

Official recommendation

Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.

Item 13

Where it was found: Galley-Deck 11 - Windjammer - Preparation Area

Official finding: Crew were not effectively monitoring cold holding temperatures of time/temperature control for safety (TCS) foods to ensure they remained at or below 41°F. The internal temperature of three vacuum-sealed packages of salami stored in an undercounter refrigerator measured 44°F using a calibrated thermometer. Additionally, the internal temperatures of ten bags of shredded cheese stored in walk-in refrigerator A-11731 ranged from 42°F to 47°F when measured using a calibrated thermometer. The bags of shredded cheese were stacked on top of each other inside an upright food transportation trolley with restricted air flow. Crew initiated corrective action.

Official recommendation

Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP, on request during inspections, knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Control Point principles, and food safety standards. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these standards; (3) By responding correctly to the inspector's questions as they relate to the specific food operation; (4) Explaining the significance of the relation between maintaining the time and temperature of TCS/PHF and the prevention of foodborne illness; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of TCS/PHF; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned.

Item 16

Where it was found: Galley-Deck 11 - Windjammer Preparation Area

Official finding: The internal temperature of three vacuum-sealed packages of salami stored in the undercounter refrigerator measured 44°F using a calibrated thermometer. Crew initiated corrective action.

Official recommendation

Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.

Item 22

Where it was found: Galley-Deck 11 - Windjammer - Warewashing Area

Official finding: The curtains separating the wash and rinse compartments inside the conveyor-type dishwashing machine were coiled and in disrepair, with small cracks throughout.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction. Ensure the warewashing machine wash and rinse tanks are equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.

Item 27

Where it was found: Galley-Deck 6 - Chops Grille

Official finding: Nonfood-contact surfaces surrounding the two grooved grills were soiled with greater than a day's worth of food residue. Crew initiated corrective action.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 24

Where it was found: Galley-Deck 6 - Chops Grille Warewashing Area

Official finding: Using a calibrated thermometer, the inspector measured the water temperature entering the flight-type warewashing machine’s final rinse manifold between 197°F to 199°F. Crew initiated corrective action.

Official recommendation

In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F).

Item 08

Where it was found: Galley-Deck 5 - Beverage Counter

Official finding: The backflow prevention device on the potable water line for the counter-mounted coffee machine was in disrepair with the atmospheric vents blocked.

Official recommendation

Maintain backflow prevention devices in good repair.

Item 27

Where it was found: Galley-Deck 5 - Forward Beverage Station

Official finding: Brown, sticky residue accumulated on surfaces inside the previously cleaned and sanitized undercounter technical compartment. Crew initiated corrective action.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 22

Where it was found: Galley-Deck 5 - Warewashing Area

Official finding: The curtains separating the wash and rinse compartments inside the flight-type dishwashing machine were coiled and in disrepair. Crew initiated corrective action.

Official recommendation

Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction. Ensure the warewashing machine wash and rinse tanks are equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.

Item 33

Where it was found: Galley-Deck 4 - Soup Preparation Area

Official finding: The deck under the left-most soup kettle was in disrepair with cracked tiles and missing grout. Crew initiated corrective action.

Official recommendation

Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.

Heating, ventilation, and air conditioning (3 findings)

Item 43

Where it was found: Ventilation-Deck 8 - Fan Room 7-08

Official finding: Gray and beige splatter residue accumulated across the entire surface of the droplet eliminator inside the HVAC unit. A pipe extended from the top of the HVAC unit, and it was not possible to remove the droplet eliminator unless the pipe was removed. Crew initiated corrective action.

Official recommendation

Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical. Keep air handling units clean.

Item 28

Where it was found: Ventilation-Deck 8 - Fan Room 7-08

Official finding: An out-of-service ice dispensing machine was stored inside the HVAC room next to the three, large white plastic containers. The equipment was not protected inside a bag or box, and the HVAC room had numerous difficult-to-clean ducts along the deckhead. Crew stated this equipment was not in service.

Official recommendation

Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination. Keep equipment and shelving in unfinished lockers or rooms clean. Do not store single-service articles and single-use articles in unfinished lockers or rooms.

Item 27

Where it was found: Ventilation-Deck 8 - Fan Room 7-08

Official finding: A layer of dust accumulated on the exterior of an out-of-service ice dispensing machine that was stored inside the HVAC room next to three large white plastic containers. The equipment was not protected inside a bag or box. Crew stated the equipment was not in service.

Official recommendation

Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.

Medical center (1 finding)

Item 11

Where it was found: Medical-Symptomatic Food Employee Isolation

Official finding: A food handler developed acute gastroenteritis (AGE) symptom onset at 0615 on 21 March 2026 and did not report to medical to begin isolation until 1135. This crew member did not work or eat inside the crew mess prior to reporting to medical. This crew member received disciplinary action.

Official recommendation

When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours.

Other inspection items (1 finding)

Item 08

Where it was found: Bar-Deck 11 - Solarium

Official finding: The backflow prevention device on the potable water line for the counter-mounted coffee machine was in disrepair with the atmospheric vents blocked.

Official recommendation

Maintain backflow prevention devices in good repair.

Swimming pools and whirlpools (1 finding)

Item 10

Where it was found: Recreational Water Facilities-Whirlpool Spa Shock Halogenation

Official finding: There were no records documenting shock halogenation conducted on whirlpool spa #1 from 2101 on 22 February 2026 until 1158 on 24 February 2026. Crew stated this facility was used for a private event and that they were unable to conduct shock halogen for a period greater than 24 hours while Solarium space was in use.

Official recommendation

For whirlpool spas and spa pools, increase the free halogen residual to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free halogen residual both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.

Gastrointestinal outbreak notices

These are official CDC Vessel Sanitation Program outbreak postings for this ship, not inspection scores. CDC generally posts a voyage when 3% or more of passengers or crew report gastrointestinal illness, or when an outbreak is otherwise of public health significance.

Official outbreak notices collected for this ship

Sailing datesCausative agentCase countsSource
2/1/2025-2/8/2025NorovirusPassengers: 160 of 2,164 (7.4%). Crew: 8 of 910 (0.9%).CDC notice
9/20-9/27, 2024SalmonellaPassengers: 180 of 2,172 (8.29%). Crew: 3 of 894 (0.34%).CDC notice
4/8-4/22, 2024NorovirusPassengers: 67 of 1,993 (3.36%). Crew: 2 of 924 (0.22%).CDC notice
01/03/2011-01/08/2011NorovirusPassengers: 150 of 2,336 (6.42%). Crew: 3 of 861 (0.35%).CDC notice
9/2/2006-9/9/2006Unknown, negative for norovirusPassengers: 227 of 2,131 (10.65%). Crew: 12 of 870 (1.38%).CDC notice

Source: CDC Vessel Sanitation Program. This page does not change the substantive content of official scores or findings.